Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals
Keisuke Nakamura1,2, , Masayoshi Ohira3, Yoshiharu Yokokawa3, Yuya Nagasawa1
Author Information
1 Department of Rehabilitation, Matsumoto City Hospital, Matsumoto, Nagano, Japan
2 Department of Health Sciences, Graduate School of Medicine, Shinshu University, Matsumoto, Japan
3 Department of Physical Therapy, School of Health Sciences, Shinshu University, Matsumoto, Japan

Keisuke Nakamura
✉ Department of Rehabilitation, Matsumoto City Hospital, 4417-180 Hata, Matsumoto, Nagano,390-1401, Japan
Email: keipons55@yahoo.co.jp
Publish Date
Received: 08-04-2015
Accepted: 28-07-2015
Published (online): 24-11-2015
 
 
ABSTRACT

Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey’s post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 ± 1.9 mL·min-1·kg-1) and the CE test (18.4 ± 1.8 mL·min-1·kg-1) were significantly higher than those during the ISTS without arm support (16.6 ± 1.8 mL·min-1·kg-1; p < 0.05). The AT-HR values during the ISTS with arm support (126 ± 10 bpm) and the CE test (126 ± 13 bpm) were significantly higher than those during the ISTS without arm support (119 ± 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults.

Key words: Sit-to-stand, cycle ergometer, anaerobic threshold, correlations, reproducibility, validity


           Key Points
  • The ISTS is a simple test that varies only according to the frequency of standing up, and requires only a small space and a chair.
  • The ISTS with arm support is valid and reproducible, and is a safe test for evaluating AT in healthy young adults.
  • For evaluating the AT, the ISTS may serve as a valid alternative to conventional CPX, using either a cycle ergometer or treadmill, in cases where the latter methods are difficult to implement.
 
 
Home Issues About Authors
Contact Current Editorial board Authors instructions
Email alerts In Press Mission For Reviewers
Archive Scope
Supplements Statistics
Most Read Articles
  Most Cited Articles
 
  
 
JSSM | Copyright 2001-2024 | All rights reserved. | LEGAL NOTICES | Publisher

It is forbidden the total or partial reproduction of this web site and the published materials, the treatment of its database, any kind of transition and for any means, either electronic, mechanic or other methods, without the previous written permission of the JSSM.

This work is licensed under a Creative Commons License Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.